Discussion on External Factors Affecting the Service Life of Hydraulic Pumps

Affect the life of the hydraulic pump many factors, in addition to its own pump design, manufacturing factors and some related to the use of pumps (such as couplings, filters, etc.) of the selection, the operation of the test run and so on. This article puts forward my own understanding. Analysis of related components  (1) coupling  (1) the choice of coupling hydraulic pump drive shaft can not withstand radial forces and axial forces, it is not allowed to directly install the pulley at the shaft end, gear, sprocket, usually Coupling drive shaft and pump drive shaft. As a result of manufacturing reasons, the coaxial pump and coupling excessive, there are deviations in the assembly, with the pump speed increase the centrifugal force to increase the deformation of the coupling, deformation and centrifugal force increases, resulting in a vicious circle, the results Produce vibration noise, thus affecting the pump life. In addition, there are other factors such as the loose coupling of the coupling pin is not timely fastened, the rubber ring wear is not timely replaced. (2) The assembly of the coupling requires that the concentricity error of the two shafts of the rigid coupling is ≤0.05mm; the coaxiality error of the two axes of the elastic coupling is ≤0.1mm; the angular error of the two shafts is less than 1 °; Keep 5 ~ 10mm distance from the pump end.  Second, the hydraulic tank  (1) the choice of hydraulic tank Hydraulic tank in the hydraulic system's main role for the storage of oil, heat, separating the air contained in the oil and eliminate foam. Select the first tank to consider its capacity, the general mobile device to take the pump the maximum flow of 2 to 3 times, fixed equipment to take 3 to 4 times; secondly consider the fuel tank level, when the system after all the hydraulic cylinders out of the tank surface should not be low At the lowest oil level, when the cylinder is retracted, the oil level should not be higher than the maximum oil level. Finally, considering the structure of the fuel tank, the partition in the conventional fuel tank can not act as sediment dirt. A vertical partition should be installed along the longitudinal axis of the fuel tank, Leaving a gap between one end of the separator and the end plate of the fuel tank so that the space between the two sides of the separator is communicated with the hydraulic oil pump inlet and outlet ports arranged on both sides of the non-communicating end separator so that the distance between the inlet oil and the oil return farthest, Hydraulic tank to play some cooling effect. (2) The installation of the hydraulic tank can be divided into upper type, side type and lower type according to the installation location. On the type of tank to install hydraulic pumps and other devices with a good stiffness on the cover, its compact structure, the most widely used. In addition, heat dissipation fins can be cast on the fuel tank shell to enhance the heat dissipation effect, that is, the service life of the hydraulic pump is increased. Side-mounted tank is the hydraulic pump and other devices installed in the tank next to the large area, but the installation and maintenance are very convenient, usually when the system flow and fuel tank capacity is large, especially when a tank to more than one hydraulic pump Used for oil supply. Due to the side tank oil level higher than the hydraulic pump suction port, it has better oil absorption. Under-tank is placed under the hydraulic pump under the tank, not only easy to install and repair, and hydraulic pump greatly improved suction capacity.  3, oil filter  (1) the choice of oil filter General size of 10μm or less of the pollutants on the pump less obvious, and more than 10μm, especially at 40μm or more when the pump life is obvious influences. The solid particles in the hydraulic oil can make the surface of the relative moving parts in the pump more aggravate. Therefore, the oil filter needs to be installed to reduce the pollution degree of the oil. Filtration requirements: axial piston pump 10 ~ 15μm, vane pump 25μm, gear pump 40μm. Pump pollution and wear can be controlled within the allowable range. At present, the use of high-precision oil filter is increasingly widespread, which can greatly extend the service life of the hydraulic pump. (2) The installation of the oil filter is divided into the following three cases: ① The oil suction filter has a simple structure. Its function is to prevent larger particles of pollutants from being sucked into the pump when the oil is sucked. Generally, a low-precision filter is used, and the highest filtration accuracy is not More than 30 ~ 50μm, in order to facilitate the maintenance of the oil filter should be installed at the top or side of the tank, should also consider the flow capacity should be more than twice the maximum flow of the hydraulic pump to prevent the pump will suck air; ② pressure oil filter The device is installed in the pressure pipeline downstream of the hydraulic pump and delivers clean pressure oil to the hydraulic system. The high-precision oil filter is usually used. The filtration precision is 3 ~ 20μm, and its circulation capacity should not be less than the maximum flow rate of the pressure oil circuit. Installed in the total oil return pipe after the oil, the system will invade the system and the pollutants generated within the system filter, usually also use high-precision oil filter. According to the recent pollution control system theory, the oil tank should reach a certain level of cleanliness. At the same time, in order to prevent over-pressure of the oil filter due to blockage, the filter should be installed to block the sender so as to timely replace the filter. Fourth, the cut-off valve  Demolition of the hydraulic pump and return pipe, the system will reverse the oil. If the hydraulic pump with a load of parking will cause the hydraulic pump to reverse, making the pump suction pipe to produce a partial vacuum, dissolved in the oil in the air out, until the next drive the system will be mixed with air, noise, cavitation, shortened Pump life, for which a stop valve is usually installed not far from the hydraulic pump drain. The stop valve should also be set to indicate that the valve has been opened electrical signal switch and only when the valve is fully open hydraulic pump to start the interlock device to ensure that the pump is not suction air when driving.  Fifth, the heat exchanger  Hydraulic system work allows the oil temperature is 15 ~ 80 ℃, the best temperature is 25 ~ 55 ℃. Hydraulic system work inevitably have to produce mechanical loss, pressure loss and volume loss, all of these losses into heat, with the exception of some of the heat through the tank, the pipe is distributed to the surrounding space most of the heat to make the tank temperature. If the oil temperature is too high, the oil will deteriorate and precipitate asphalt and other debris. The viscosity of the oil will drop. The internal and external leakage of the hydraulic pump will increase. The lubricity of the oil is poor. The oil film will be easily damaged. The wear of the sliding parts in the pump will be aggravated. Service life, so the system temperature rise is too high, you must set the oil cooler. Cooler is divided into air-cooled, water-cooled and ice-cold, depending on the choice of use. Conversely, if the oil temperature is too low, the oil viscosity increases, the frictional resistance increases, the hydraulic pump starts, oil absorption difficulties, affecting the use of the pump. In the area below 0 ℃ before starting the pump should be heated to 15 ℃ above the oil and pass to the pump body until the temperature of each component to rise above 15 ℃ and then start the hydraulic pump, this requires the bottom of the fuel tank to set a heater level Guarantee always soaked in oil below.  Ⅵ operation precautions  (1) before the operation ① whether the installation of hydraulic pump is accurate and reliable, the screws are tightened, the coupling installation meets the requirements; ② whether the pump body filled with oil; ③ whether the steering pump with oil Mouth coincide; ④ hydraulic system safety valve is transferred to the specified pressure value.  (2) Start-up can not be started at full speed during start-up, the system should be unloaded in the state of the prime mover jog switch after several consecutive no-load operation, the purpose of the pipeline is to exclude air as clean as possible, no-load operation 1 ~ 2min no abnormal phenomenon after gradual loading, the loading process should be no abnormal vibration, noise and leakage, or immediately shut down inspection and analysis, troubleshooting.  (3) After the end of the run if the pump should not be long-term discharge of the pump fluid, and then filled with a lower acid content of oil, exposed surface coated with anti-rust oil, Anti-dirt into. From the above analysis we can see that the life of the hydraulic pump is damaged by its own internal parts, the degree of wear and tear and its decision, but its internal parts damaged, the degree of wear and tear directly affected by the use of external components, the rational use of hydraulic pump related external components, the correct operation Using a hydraulic pump can greatly improve the life of the pump.

This entry was posted in on